Re: [Wien] IRelast error in C_ana_elast_lapw

2022-09-08 Thread Laurence Marks
Live by the computer, die by the computer. If you treat IRelast as a black box that will give you "truth", then things can go wrong -- obviously they have! What you need to do is look at the numbers for the energy versus strain yourself. Plot them -- do they look sensible or not? Use something li

Re: [Wien] IRelast error in C_ana_elast_lapw

2022-09-08 Thread Morteza Jamal via Wien
This error comes from this fact that minus value of c12 for your calculations(i think for c12 less than -50) leads to Inverse matrix of ELC-matrix is not calculate correctly. With best, Morteza - Forwarded Message - From: "m_jama...@yahoo.com" To: "wien@zeus.theochem.tuwien.ac.at"

Re: [Wien] IRelast error in C_ana_elast_lapw

2022-09-08 Thread reyhaneh ebrahimi
I think your error is due to the results of (c11+2c12) = -0.091 (GPa) (also the value of c12 = -58.679 (GPa)) for order of fit=4. Because this value does not satisfy the Born stability criteria. In other words this value should be positive to have the compound with mechanical stability. Howev

Re: [Wien] IRelast error in C_ana_elast_lapw

2022-09-08 Thread Morteza Jamal via Wien
1) i think your results are not correct. 2) usually, results of order of fit= 3 are acceptable. 3) error comes from minus value of c12 = -58. for order of fit= 4 ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at

[Wien] IRelast error in C_ana_elast_lapw

2022-09-08 Thread AJAY SINGH VERMA
Dear all, While running C_ana_elast_lapw for my compound, I am getting following error given below in order of fit 4. Result for order 2 and 3 is being shown properly. Output order file has been attached. Kindly help. ORDER OF FIT IS : 4 , At volume = 2365.41197 (bohr^3) (c11-c12) =