At the moment you have to use
init -prec 1 instead of 1n.
After that, you can rerun
x kgen with 30 total points, which should lead to a 6 6 1 mesh.
-
I'm not aware of the other problem, but maybe Oleg Rubel knows more ...
Am 08.04.2024 um 23:48 schrieb
Dear Prof.Blaha,It is on my home computer with wien2k_23.And there is another error existing when i do the scf of GaAs following the guide of "wien2k + w2wannier+wannier90".I can't use LDA for initialization, and it will lead an error in scf calculation. But I can use PBE and WC.They perform
Hi,
Where does this happen and with which version of WIEN2k.
It is on the workshop nodes or on your home computer with WIEN2k_23.
I'm aware of this problem and I think I fixed in on the workshop nodes.
Of course it will still happen when using WIEN2k_23 and only the next
release will have
Dear all,
I am doing the latest exercise 6(MgO surface slab),and there is a error when do
"init_lapw -prec 1n"
STOP KGEN ENDS
NUMK: 1000
basic k-mesh: 12, 12, 2 = 288, kfactor = .1000
NUMBER OF K-POINTS IN WHOLE CELL: (0 for 3 divisions of K, -1 for delta-K)
At line 243 of
I would suggest starting by plotting the band structure and deciding which
energy window you would like to get wannierized. For example, if we are
describing sp3 bonding in GaAs or Si and would like to model the valence and
conduction band, then I would ask for 4xN Wannier functions (4=1s+3p,
5 matches