Re: [Wien] Convergence of magnetic moment

2018-05-23 Thread Laurence Marks
You have to be careful about semantics (language) here. In the user guide -cc and -ec are referred to as "Charge Convergence" and "Energy Convergence", but they could better be written as "Charge Consistency" and "Energy Consistency". The scf iteration will continue until neither changes, i.e.

Re: [Wien] Convergence of magnetic moment

2018-05-23 Thread Peter Blaha
-0.00013 is "zero" ! Much more important: is k-mesh and RKMAX fully converged ! It is converged only if NOTHING changes when you increase them. A permanent small neg or positive MM could hint to "problems" of the BZ integration: better k-mesh, unshifted mesh, change from TETRA to TEMP with

[Wien] Convergence of magnetic moment

2018-05-23 Thread Rui Costa
Dear wien2k users, Can I converge simulations to the last decimal place in the magnetic moments? Or do the numerical errors stop me from achieving such accuracy? For example, I have made a calculation with -cc 0.000 001 but i get: :MMTOT: SPIN MAGNETIC MOMENT IN CELL = -0.00013 :MMTOT: