Re: [Wien] Fwd: XMCD_Optic_error

2018-06-14 Thread Peter Blaha
Thank you very much for looking into this issue and fixing it. Yes, a student was extending optics to HELOs (to allow a proper calculation at higher excitation energies) about 2 years ago and apparently he broke the XMCD option. The fix will be included in WIEN2k_18, which I hope to release

Re: [Wien] Fwd: XMCD_Optic_error

2018-06-13 Thread Gavin Abo
The XMCD calculations seem to be seriously broken in WIEN2k 17.1.  I suspect that any structure will run into an XMCD error similar to: username@computername:~/wiendata/testXMCD$ x optic -so -up  emin,emax,nbvalmax  -5.00 3.00  XMCD selected for atom 

[Wien] Fwd: XMCD_Optic_error

2018-03-04 Thread Jyoti Thakur
Respected Sir I am trying to run the XMCD calculations for simple case of bcc Fe. I saw in WIEN2k mailing list related to XMCD problems; https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg07677.html I have followed these steps: 1) runsp_lapw -p 2) runsp_lapw -so -p after initso_lapw