This message means that at some points of space, the exact tau is
smaller than tauw (Weizsaecker tau, which is considered as a lower bound
for the exact tau), which in principle should not occur. However, due to
relativistic effects or numerical inaccuracy this can happen, but this
should be of
Hi,
I'm using WIEN2k_14.2. I ran a mBJ calculation without any error messages.
However, in the dayfile, there are a few lines (see below) that appear in
every iteration. I searched the mailinglist and found a few threads
discussing tauwrong. In one email, it was mentioned that so long as
tauwrong
2 matches