Dear all,
I am working on the magnetic properties of rare earth?iron compounds. I have a
question in structure optimization.
How to set the U and J parameters when using LDA+U method, since U and J can?t
be calculated by ab initio way? So I just set U=J=0. If it is reasonable, then
is it
I am working on the magnetic properties of rare earth?iron
compounds. I have a question in structure optimization.
How to set the U and J parameters when using LDA+U method, since U
and J can?t be calculated by ab initio way? So I just set U=J=0. If
it is reasonable, then is it
Dear H. Pang,
there is a paper about U determination by Madsen and Novak on the wien2k page:
http://www.wien2k.at/reg_user/textbooks/
They suggest that you put J=0 and choose some positive value of U.
Also there was a discussion on the list about U determination some
months ago, search the list.