Blair, Where can I get this outdoor, shielded, flooded, cat5 with drain wire for about $80? That is about what I'm paying now for simple outdoor rated cat5. Thanks, Blair Davis <[EMAIL PROTECTED]> wrote: Well, I use a outdoor, shielded, flooded, cat5 with drain wire.About $80 or so per 1
unday, March 26, 2006 9:54 PM
To: 'WISPA General List'
Subject: RE: [WISPA] CPE...Cat5...grounding
Can't you just use shielded Cat5E cable to do this. We use it on all tower
installs but not for CPE's.
Rick Harnish
President
OnlyInternet Broadband & Wireless, Inc.
260-827-
==
- Original Message -
From: "Brian Rohrbacher" <[EMAIL PROTECTED]>
To: "WISPA General List"
Sent: Sunday, March 26, 2006 9:07 PM
Subject: [WISPA] CPE...Cat5...grounding
Ok, I am searching for cat5 with ground wire attached.
Well, I use a outdoor, shielded, flooded, cat5 with drain wire.
About $80 or so per 1000ft. The drain wire is awg 24 or so, but, it
serves the purpose of bleeding off the static charge and protecting the
ethernet port on the radio and the computer/router. I have had no
ethernet port damage o
.com
==
- Original Message -
From: "Rick Harnish" <[EMAIL PROTECTED]>
To: "'WISPA General List'"
Sent: Sunday, March 26, 2006 10:53 PM
Subject: RE: [WISPA] CPE...Cat5...grounding
Can't you just use shielded Cat5E cable
MAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Mike Bushard, Jr
Sent: Sunday, March 26, 2006 10:19 PM
To: 'WISPA General List'
Subject: RE: [WISPA] CPE...Cat5...grounding
I have been looking for Shielded Cat5e with a ground wire attached for a
long time also. I was thinking of callin
Behalf Of KyWiFi LLC
Sent: Sunday, March 26, 2006 8:23 PM
To: WISPA General List
Subject: Re: [WISPA] CPE...Cat5...grounding
I know this is something every WISP should be interested in
using. It would be great to have an outdoor rated Cat5 cable
with an attached 10awg. A reasonable price IMO for a
==
- Original Message -
From: "Brian Rohrbacher" <[EMAIL PROTECTED]>
To: "WISPA General List"
Sent: Sunday, March 26, 2006 9:07 PM
Subject: [WISPA] CPE...Cat5...grounding
Ok, I am searching for cat5 with ground wire attached.
How well do you think a coax would work
Ok, I am searching for cat5 with ground wire attached.
How well do you think a coax would work to ground the CPE?
http://www.computercablestore.com/detail.aspx?ID=2098
It's not like I am trying to protect it from lightning (good luck) I
just want somewhere for the static to go. I could brea