Hi folks,
I am almost finished a dissector for the IEEE1905 Multi-AP technical
specification draft from August 2017. The work was done for an
organization in the industry. It is pretty complete and has undergone
testing with real traffic.
Unfortunately, they make references to elements in IEEE802
I'm investigating a performance problem with the TRANSUM dissector. I'd like
to measure the accumulated time taken to execute a function in a Release build.
My basic idea is to do something like this:
guint32 execute_time_us;
.
.
start_stopwatch(&execute_time_us);
function_call_to_be_measured(
On 13-10-2017 21:50, Gerald Combs wrote:
Before we migrated away from NMake, epan/Makefile.nmake built the assembly
versions of various routines for x86 (but not x64) defined in
epan/asm_utils_win32_x86.asm. Should we resurrect it in epan/CMakeLists.txt or
get rid of it along with the NASM d