On 3/26/2010 12:10 AM, Rohit Sharma (SIDC) wrote:
> So is there no way I can do this, even if I could HIDE the feature in
> selection tree that would work for me.
You can hide a feature by keeping its feature level at 0 or by using the
Remove control event.
--
sig://boB
http://joyofsetup.com/
On 3/27/2010 1:26 AM, Dariel Marlow wrote:
> 1. Does WIX support MSI files larger than 4GB?
MSI doesn't. The schema limits file sizes to 31 bits.
--
sig://boB
http://joyofsetup.com/
--
Download IntelĀ® Parallel St
On 3/26/2010 2:12 PM, little.forest wrote:
> 2. Those two DLL files will cause 'Error 2836' directly. But the manifest
> file will cause the installer showing 'The system can not find the file
> specified.' first then showing the 'Error 2836'. So this is slightly
> different from those two DLL f
We're considering dropping the x64 WiX .msi package as it's rarely
needed. See
http://www.joyofsetup.com/2010/03/27/wix-msbuild-v2-0-and-x64-systems/
and comment if dropping it would affect you.
--
sig://boB
http://joyofsetup.com/
-
The command line order is wrong from a first glance. We have not been happy
with the way heat handles its command line (there is a bug filed). Please
try to reorder your command line according to the help given.
Yours:
$ heat project -pog:Binaries -var var.AceCmdCom -dr AceCmdCom -ag -suid
-cg ACE
5 matches