m
> To: wix-users@lists.sourceforge.net
> Subject: Re: [WiX-users] No reboot prompt but log shows reboot scheduled
>
> Swandog wrote:
> > After installation completes, there was no reboot prompt. The DLL was
> > replaced. I was unable to reproduce the issue where the COM DLL
Swandog wrote:
> After installation completes, there was no reboot prompt. The DLL was
> replaced. I was unable to reproduce the issue where the COM DLL was not
> replaced but what is worse, it's not clear why there was no reboot prompt and
> how the MSI was able to replace the DLL while it wa
Hi:
I have an MSI that sets up a Web site (IIS) that uses several COM DLLs and a
Windows service (not Web service). The MSI is used for new installations as
well as upgrade existing installations. Occasionally upgrades are not
completely successful because a COM DLL is loaded in memory a