ative, non-managed custom BootstrapperApplication.
-Original Message-
From: Roy Chastain [mailto:r...@roychastain.org]
Sent: Friday, July 08, 2011 7:13 AM
To: wix-users@lists.sourceforge.net
Subject: Re: [WiX-users] What is the purpose of the MbaNetfxPackageId and
MbaPreqPackageName variables
> We would never do something as silly as REQUIRE a native application
to install the .NET
> Framework just to use the WiX toolset's bootstrapper, Burn.
Well, I did not think so, but the first response through me off. The
answer told me it was use by Burn and that I was off the beaten path.
Imagi
6, 2011 10:31 PM
> To: General discussion for Windows Installer XML toolset.
> Subject: Re: [WiX-users] What is the purpose of the MbaNetfxPackageId and
> MbaPreqPackageName variables
>
> The managed BA host (MBA) definitely supports .NET 3.5.
>
> Remember, you don't use th
. :)
John
Wintellect
http://www.wintellect.com
+1-877-968-5528
-Original Message-
From: Rob Mensching [mailto:r...@robmensching.com]
Sent: Wednesday, July 06, 2011 10:31 PM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] What is the purpose of the
The managed BA host (MBA) definitely supports .NET 3.5.
Remember, you don't use the MBA unless you are writing your BA in managed
code. I wrote the WiX toolset's BA in managed code to demonstrate how it can
be done and I like .NET Framework 4.0 so I chose to write the BA using it.
If you would rat
On 06-Jul-11 13:26, Roy Chastain wrote:
> Are you trying to tell me that the Burn bootstrapper REQUIRES .NET 4.0
> to run?
No, it doesn't require any version of .NET. Obviously, if you want to
use a managed BA, .NET is required and as I said above:
> note that the current managed BA has
> only
> They're used by the Burn managed bootstrapper app to manage installing
> .NET. They're still needed but note that the current managed BA has
only
> supported (tested/validated) .NET 4, not 3.5. At the moment, you're in
> uncharted waters.
Are you trying to tell me that the Burn bootstrapper R
On 06-Jul-11 08:50, Roy Chastain wrote:
> What are the purposes of these two variables and is this something that
> needs to be emulated when authoring an install with a prereq of .NET 3.5
> SP1?
They're used by the Burn managed bootstrapper app to manage installing
.NET. They're still needed but
The fragment to install .NET Framework 4.0 used in the WiX install has
the following
What are the purposes of these two variables and is this something that
needs to be emulated when authoring an install with a prereq of .NET 3.5
SP1?
---