Hi Bill, Joe, Steve and all other participants in this forum
RE: Sub process error
I listened a long period of time on two WSJT-X FT4 instances at the
same time. There were no errors. I listened at the "normal" decoding
level. At the time (20:04) when I changed the level of decoding to
"deep"
Hi Enrique,
http://physics.princeton.edu/pulsar/k1jt/Reported_bugs.txt
1. The 64-bit executable for Windows resets the audio input gain to
100% on program startup, when the input audio device is changed, and
when switching to a new configuration.
73`s Joe Jozef LB1HI
On 03/05/2019 23:50, Enriqu
.
Recording audio should be at 0dB.
de Mike W9MDB
On Tuesday, April 30, 2019, 6:55:30 AM CDT, kf8my--- via wsjt-devel
wrote:
It also does it in Win7, audio sound recording to max on restart.
Mike/kf8my
-Original Message-
From: Joe, LB1HI
To: wsjt-devel
Sent: Tue, Apr 30, 2019 6:46
Hi,
Even with the setting NAvg=1 the distance between the lines separating
the period is "quite small".
But first, the technical functionality of the software is a priority.
In the future, when it will work as it should. It would be nice to have
"cosmetic" treatments for visual appearance and
Hi,
Another observed drawback is that after each WSJT-X restart, previously
pre-set audio (Win 10 64 bit) signal input level of the sound card
changes. It changes spontaneously. It changes to a maximum - 100% of
the level setting range.
73`s Joe
_
Hi Tom
QRG 40 mtr band 7047
73 LB1HI, Joe
On 30/04/2019 11:07, Tom Ramberg via wsjt-devel wrote:
I just finished one contact on 20 meter. Now checking 40. What is the frequency
for 40 meters?
De OH6DA & OH2K Tom
Sendt fra min iPhone
___
wsjt-dev
Hi,
FT4 Sub-process error. There was twice until now.
73`s Joe, lb1hi
At line 41 of file C:\Users\bill\src\k1jt\wsjtx\lib\ft4\ft4_downsample.f90
Fortran runtime error: Index '-2147483648' of dimension 1 of array 'cx'
below lower bound of 0
Error termination. Backtra