Question #291538 on Yade changed:
https://answers.launchpad.net/yade/+question/291538
Status: Answered => Solved
hjz confirmed that the question is solved:
Hi Durize,
Thank you for your answer. It is helpful when I turn the
GlobalStiffnessTimeStepper' safety coefficient down.
hjz
-
Question #291538 on Yade changed:
https://answers.launchpad.net/yade/+question/291538
hjz posted a new comment:
Bruno,
I'm very sorry. I will be careful next time.
hjz
--
You received this question notification because your team yade-users is
an answer contact for Yade.
Question #291538 on Yade changed:
https://answers.launchpad.net/yade/+question/291538
Bruno Chareyre posted a new comment:
Please don't ask the same question multiple times (actually there is not even a
question in this one ;) ).
If you don't receive answers you may check (especially point 3):
ht
Question #291538 on Yade changed:
https://answers.launchpad.net/yade/+question/291538
Status: Open => Answered
Jérôme Duriez proposed the following answer:
Hi
Your problem is quite complex in the sense there is a lot of operations behind
what you're doing, and behind the symptoms you're exp
New question #291538 on Yade:
https://answers.launchpad.net/yade/+question/291538
Hi all,
I have some question about the young modulus in triaxial test using
Law2_ScGeom_FrictPhys_CundallStrack.
When I increase the particles' young modulus from MPa to GPa, the particle
cross the wall
5 matches