Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-11-07 Thread Launchpad Janitor
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Open => Expired Launchpad Janitor expired the question: This question was expired because it remained in the 'Open' state without activity for the last 15 days. -- You received this question notifi

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-22 Thread Luc OGER
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Expired => Open Luc OGER is still having a problem: i still need an answer so: please help me by just checking if the series of mechanical parameters attribution are correct as they are not playing

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-22 Thread Launchpad Janitor
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Open => Expired Launchpad Janitor expired the question: This question was expired because it remained in the 'Open' state without activity for the last 15 days. -- You received this question notifi

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-07 Thread Luc OGER
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Answered => Open Luc OGER is still having a problem: Hi Jérôme, here the full code and the table for the batch test with only the capillray pressure changes : 1000 and 5000 exactly the same particle

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-06 Thread Jérôme Duriez
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Open => Answered Jérôme Duriez proposed the following answer: O.engines does not tell much in itself here. Particle size considerations are at least as much important: with "big" particles, the behav

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-05 Thread Luc OGER
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Answered => Open Luc OGER is still having a problem: Hi Jerôme, my engine is exactly the same as in the reference [*]: #for linear model only O.engines=[ ForceResetter(),

Re: [Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-05 Thread Jérôme Duriez
Question #693194 on Yade changed: https://answers.launchpad.net/yade/+question/693194 Status: Open => Answered Jérôme Duriez proposed the following answer: Hi, If I remember correctly, the biggest difference between Law2_ScGeom_CapillaryPhys_Capillarity (which I'm more used to, personnally)

[Yade-users] [Question #693194]: use of Law2_ScGeom_CapillaryPhys_Capillarity with variable pressure does not change results

2020-10-01 Thread Luc OGER
New question #693194 on Yade: https://answers.launchpad.net/yade/+question/693194 Hello, I am trying a simple test case with rolling large spheres on top of small ones by using the two 'classical capillary exemples present in the directory : ./examples/capillaryLaplaceYoung/CapillaryPhys-example