Re: [Yade-users] [Question #702407]: CGAL ERROR: assertion violation! when running HM coupling

2022-07-23 Thread Launchpad Janitor
Question #702407 on Yade changed: https://answers.launchpad.net/yade/+question/702407 Status: Open => Expired Launchpad Janitor expired the question: This question was expired because it remained in the 'Open' state without activity for the last 15 days. -- You received this question

Re: [Yade-users] [Question #702407]: CGAL ERROR: assertion violation! when running HM coupling

2022-07-07 Thread Ziyu Wang
Question #702407 on Yade changed: https://answers.launchpad.net/yade/+question/702407 Status: Answered => Open Ziyu Wang is still having a problem: Hi, For the case of flow pressure is 50MPa,there was no problem most of the time, but in the end, another error was reported: #

Re: [Yade-users] [Question #702407]: CGAL ERROR: assertion violation! when running HM coupling

2022-07-07 Thread Ziyu Wang
Question #702407 on Yade changed: https://answers.launchpad.net/yade/+question/702407 Ziyu Wang posted a new comment: Hi,Bruno. I change the time-step from .5*PWaveTimeStep() to .1*PWaveTimeStep(),and it seems fine right now(I haven't got the final result yet).I will give feedback when I get

Re: [Yade-users] [Question #702407]: CGAL ERROR: assertion violation! when running HM coupling

2022-07-07 Thread Bruno Chareyre
Question #702407 on Yade changed: https://answers.launchpad.net/yade/+question/702407 Status: Open => Answered Bruno Chareyre proposed the following answer: Hi, This error suggests huge overlaps between some spheres, such that in some pore throats the intersected solid area is more than the

[Yade-users] [Question #702407]: CGAL ERROR: assertion violation! when running HM coupling

2022-07-07 Thread Ziyu Wang
New question #702407 on Yade: https://answers.launchpad.net/yade/+question/702407 Hi, I am trying to do HM coupling with cylinder sample.Under the confining pressure of 30MPa,I have get the result of which the flow pressure is 10,20,30MPa. However,when I add the flow pressure to 40 and 50MPa,I