This sounds like
http://bugs.opensolaris.org/bugdatabase/view_bug.do?bug_id=6894775.
It seems this can be avoided by switching to an LSI card that uses
mpt_sas. For example, the 9211.
However, certain drives, such as the Western Digital
WD2002FYPS-01U1B0, can also result in the behavior .
A
> are you using comstar or the old iSCSI target (iscsitadm) to provision
> targets?
I'm using zfs set shareiscsi=on to confugure the logical units and COMSTAR for
the rest on the OpenSolaris side. The targets are initiated on Solaris 10 with
iscsiadm.
This thing was humming right along and all
I have a storage server with snv_134 installed. This has four zfs file systems
shared with iscsi that are mounted as zfs volumes on a Sun v480.
Everything has been working great for about a month, and all of a sudden the
v480 has timeout errors when trying to connect to the iscsi volumes on the