On Wed, 28 Jan 2009, Cuyler Dingwell wrote:
In the process of replacing a raidz1 of four 500GB drives with four
1.5TB drives on the third one I ran into an interesting issue. The
process was to remove the old drive, put the new drive in and let it
rebuild.
The problem was the third
In the process of replacing a raidz1 of four 500GB drives with four 1.5TB
drives on the third one I ran into an interesting issue. The process was to
remove the old drive, put the new drive in and let it rebuild.
The problem was the third drive I put in had a hardware fault. That caused
both