ff> I have check the drives with smartctl:
ff> ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
ff> 1 Raw_Read_Error_Rate 0x000f 115 075 006Pre-fail
Always - 94384069
ff> 5 Reallocated_Sector_Ct 0x00
Frank Fischer wrote:
> After having massive problems with a supermicro X7DBE box using AOC-SAT2-MV8
> Marvell controllers and opensolaris snv79 (same as described here:
> http://sunsolve.sun.com/search/document.do?assetkey=1-66-233341-1) we just
> start over using new hardware and opensolaris 20
After having massive problems with a supermicro X7DBE box using AOC-SAT2-MV8
Marvell controllers and opensolaris snv79 (same as described here:
http://sunsolve.sun.com/search/document.do?assetkey=1-66-233341-1) we just
start over using new hardware and opensolaris 2008.05 upgraded to snv94. We