---------- Forwarded message ----------
From: Santosh Kumar Sundriyal <[email protected]>
Date: Wed, Oct 27, 2010 at 1:10 PM
Subject: Re: Fwd: Please mail to Seisan Group
To: Jens Havskov <[email protected]>
Cc: [email protected]


Sir

I am using the program called *xspmft.f *
written by R. B. Herrmann. A detail is given below (as in Surface manual of
seisan). However I have solved  the problem by converting the data (100
SPS) in SAC format and then decimating there by factor 5 i.e converting  in
20 SPS.
Just want to know  if this facility is there in Seisan?
Will it lose some information for period 10-25 sec. ( teleseismic events)

warm regards

Santosh Kumar.

*details of  Multiple Filter Analysis using xspmft.f*

One of the methods available for calculating group velocities is the
Multiple Filter

Technique (MFT). This technique is applied on multiply dispersed signals to
isolate

group velocities as a function of time. There exist numerous computer
programs to

accomplish this. *Here, the program called *
*xspmft **written by R. B. Herrmann is used.*

The program is controlled from a command line with several options. Of the
available

options, only three are used here (A description of other options can be
found in the

full manual written by R. B. Herrmann)

To run the program, two input files are required. One contains the waveform
file

(spectral amplitudes) prepared in stage (I), and the second contains the
frequencies /

periods for which the group velocities will be calculated ( i.e. filter
centre frequencies

/ periods). An example of the command to run the program is given below.
*

xspmft –v –V –C xspm.d < com_spec.out
*

where,
*

xspm.d
*is an input file containing the filter centre frequencies*

com_spec.out
*is the file containing the spectral amplitude data from stage (I)*

-v
*is an option to have the spectral amplitudes annotated*

-V
*is an option to create an ASCII output file containing the dispersion data*

-C
*xxxx is an instruction to read the filter centre frequencies from the file
xxxx

(where xxxx is xspm.d in the example given above)

On Tue, Oct 26, 2010 at 3:26 PM, Jens Havskov <[email protected]>wrote:

>
> santosh
>
> which program are you trying to recompile ?
>
> jens
>
> On Sun, 24 Oct 2010, Santosh Kumar Sundriyal wrote:
>
>
>> Dear Sir,
>>
>> I am doing  doing Multi Filter Analysis using code xspmft.f and following
>> Short Manual of Surface Wave Group Velocity Inversion. In the xspmft.f
>> code
>> , the number of points in FFT and  - the number of frequencies are 1024
>> and
>> 513 fixed respectively ( a program by Hermann) .  In our work of  spectral
>> analysis we are using surface waves (i.e. Rayleigh,Love wave)  the window
>> length is very long and getting these two parameters are  8192, 4097
>> respectively in the com_spec.out file. I have tried to recompile  the
>> program in Sun system with changing  these two parameters but code is not
>> running. and error message comes. Please suggest me how could we fixed
>> these values as a code given for
>> distant earthquake or how we could recompile properly,
>> With Regards,
>>
>> Santosh Kumar
>> ISR, Gandhinagar, Gujarat,
>> India
>>
>>
>>
>>
>> --
>> Santosh Kumar
>> ISR,Gandhinagar.
>>
>>


-- 
Santosh Kumar
ISR,Gandhinagar.



-- 
Santosh Kumar
ISR,Gandhinagar.
_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan

Reply via email to