laura
the message is probably due a wong station and component name in your
parameter file. remeber that if you e.h. have a component BHZ then it must
be written BH Z in parameter file since seisan earlier ysed 4 character
component codes
jens
On Thu, 27 Jan 2011, Vetri Laura Maria Virginia wrote:
I need to use Spec program in semiautomatic manner to analyze a lot of
wavenumbers.
I made a dirf of waveform files to use and I use filenr.lis as input file
name.
Unfortunately it seems that the program can?t read the station name in the
waveform files or something like that
The message error is: Station and component not found in trace fileĀ TRMP1S
Z
Laura Maria Vetri
?? ?
Geophysicist
?? ?
Eni - E&P Division
GEPO Dept.
via Emilia, 1
20097 S. Donato M.se (Mi)
Tel. +39 02 520
62145
Fax +39 02 520 61862
?? ?
eni spa
Sede Legale
Piazzale Enrico Mattei, 1
00144 Roma - Italia
Capitale sociale
euro 4.005.358.876,00 i.v.
Codice Fiscale e Registro Imprese di Roma n. 00484960588
Partita IVA n. 00905811006
R.E.A. Roma n. 756453
Sedi secondarie:
Via Emilia, 1 e Piazza Ezio Vanoni, 1
20097 San Donato Milanese (Milano) ? Italia
eni.com
____________________________________________________________________________
Message for the recipient only, if received in error, please notify the
sender and read http://www.eni.com/disclaimer/
_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan