Dear Sezim,
We modified the velmenu.for code to be able to handle OBS depths. In fact, it
handles depths up to -999 meters, like this:
LSo13719.70N 3215.91W-999
but not beyond, like this:
- LSo13719.70N 3215.91W3999
In case you want to modify velmenu.for to handle the second type of line, here
is what I did:
At line 270 (or 271, depending on your version), change
&'(a4,f7.4,a1,1x,f8.4,a1,1x,i4,1x,i1,1x,i3,1x,f5.2,2x,f5.2)'
to
&'(a4,f7.4,a1,1x,f8.4,a1,i5,1x,i1,1x,i3,1x,f5.2,2x,f5.2)'
And, at line 338 (or 339), change
textout(23:23)= ' '
to
textout(23:23)=text(1:1)
Note that this won't work with weirdly written depths, like:
- LSo13719.70N 3215.91W 99
for -99 meters depth
I contacted Lars, and I think that future versions of SEISAN will have this
included.
However, since the hypocenter implementation used in SEISAN moves all of the
stations to sea level and introduces a time shift to account for that, we also
shifted our stations up to be centered around sea level, to minimize ray
geometry problems (our water depth is significant compared to the earthquake
depths).
Cheers,
Wayne Crawford
On 8 Mar 2012, at 16:52, Ivonne Gabriela Arroyo wrote:
> Hi Sezim,
>
> Some years ago I had some experience on deriving a minimum 1-D model for an
> array that included both, OBS and land stations and with Velest. I used
> Velest directly, and not through Seisan, but I guess it is the same.
> If things haven't changed and the code hasn't been edited, Velest can't
> handle OBS. Then we used a trick: we pull the whole problem (all stations,
> starting model AND original hypocenters upwards), above sea level. That is,
> we artificially added some km to the whole array (4 km in my case). After
> modeling, we then substracted the added km again everywhere: to report the
> hypocenters, and to use the velocity model as reference for tomography, for
> example.
> Hope this might help! Greetings,
>
> Ivonne
>
>
> ------
> Ivonne G. Arroyo
> Helmholtz-Zentrum für Ozeanforschung Kiel (GEOMAR)
> Wischhofstr. 1-3, Geb.8B
> 24148 Kiel, Germany
>
>
> ----- Ursprüngliche Nachricht -----
> Von: [email protected]
> Datum: Donnerstag, 8. März 2012, 10:05
> Betreff: [seisan] VELEST with Ocean Bottom Seismometers
> An: [email protected]
>
> > Hello ,
> >
> > I am using Velest in seisan to calculate 1D minimum velocity
> > model for a list of
> > hypocenters calculated with both land and sea seismometers. When
> > I run velest
> > it creates a file (STATION.STA) with stations and elevations using
> > STATION0.HYP. Even though I placed "-" sign before each ocean bottom
> > seismometer in STATION0.HYP, STATION.STA file that contains both
> > stationscoordinates and elevations for the VELEST run does not
> > include "-" signs. So I
> > think the iteration is made without considering the negative
> > elevations of OBO.
> > Also I give the value 1 to IUSEELEVEL in the *.CMN file to use
> > the elevations
> > but there is no change in STATION.STA file. Can anybody help me
> > on this
> > subject? Thank you all...
> > --
> > Sezim E. Guvercin
> >
> > Bogazici University : KANDILLI OBSERVATORY AND EARTHQUAKE
> > RESEARCH INSTITUTE
> > DEPARTMENT OF GEOPHYSICS : Çengelkoy ISTANBUL :
> > +90.216.516.33.03
> >
> >
> >
> >
> >
> > _______________________________________________
> > seisan mailing list
> > [email protected]
> > http://mailman.uib.no/listinfo/seisan
> > _______________________________________________
> seisan mailing list
> [email protected]
> http://mailman.uib.no/listinfo/seisan
____________________________