Hello,

Do you have PITSA?

Pitsa can do it easily, but you need to know the sensitivity of the sensor in 
V/m/s

For example, using a Lennartz sensor LE3D-lite

400 V/m/s= 0.4 uV/nm/s

Scale factor= 32uV/count

So you can go from counts to m/s and you can do the integration or the 
differentiation to get displacement of acceleration.

I hope this helps

Saludos,

[cid:[email protected]]Waldo Taylor Castillo
                          Geólogo y sismólogo - UEN PySA
                     Área de Amenazas y Auscultación Sísmica y Volcánica
                     Tel: 2695-6522, Fax: 2695-5193

De: [email protected] [mailto:[email protected]] En nombre de 
Edwar Alberto Zambrano Martinez
Enviado el: Friday, November 23, 2012 2:13 PM
Para: [email protected]
Asunto: [seisan] Convert a signal in counts to dispacement (m), velocity (m 
s-1), aceleration (m s-2)

Hi,

Could you help me how convert a signal in counts to dispacement (m), velocity 
(m s-1), aceleration (m s-2).

I appreciate your cooperation and assistance

Thanks

--
Edwar Alberto Zambrano Martinez
Ingeniero Civil -UFPS
Magíster en Ciencias de la Tierra con énfasis en Geofísica -EAFIT

________________________________
Este mensaje de correo electrónico, incluidos los archivos adjuntos, es para el 
uso exclusivo de la persona a la que se ha enviado, y puede contener 
información que sea confidencial o protegida legalmente. Si usted no es el 
destinatario, o ha recibido este mensaje por error, no está autorizado a 
copiar, distribuir, o utilizar de alguna manera este mensaje. Por favor 
notifique inmediatamente al remitente por correo electrónico y suprimir 
permanentemente este mensaje y los archivos adjuntos. No se otorga ninguna 
garantía de que este e-mail esté libre de errores o virus.
INSTITUTO COSTARRICENSE DE ELECTRICIDAD

<<inline: image001.jpg>>

_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan

Reply via email to