beatriz

it all depends on the other trigger parameters. you might have two real detections 9s apart. in any case i do not suppose you are triggering on one station only. even if you get few too many triggers in one channel, the network trigger will only use the common triggers.

jens

On Wed, 13 Nov 2013, Beatriz Gaite wrote:

Dear all,

I am detecting events with CONDET CAR in a 1-day-long mseed continuos data
in a Seiscomp strutured database. It works, but I detect the same event
twice. I have defined the trigger interval to 90 s (MIN TRIG INTERVAL 90.) in condet.par file, but I get triggers separated 9 s that correspond to
the same event. If I define (MIN TRIG INTERVAL      15.) I obtain the same
triggers.

Example of triggers that correspond to the same event:
20130910034215.630
20130910034224.550

Have anyone found it before? How can I solve it?

Many thanks in advance.


--
Beatriz Gaite Castrillo
Earth Sciences Institute Jaume Almera (CSIC)
Lluis Solé i Sabaris s/n
08028, Barcelona
Spain

+34 934095410 (ext. 262)

_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan

Reply via email to