Dear Community.
I believe I have reported this bug before, but got no feedback. Whenever I run CORR in continuous mode, there is systematically an event missing from corr_cont.out that is listed in corr.out. This is inconvenient because the routine I wrote builds a report output which lists the detected events and their correlation coefficient, which is listed only in corr_cont.out. Also, is there a way I can get more precision in corr_cont.out correlation coefficient? I need one more digit like we get in CONDET output. Thank you for your feedback and suggestions. Best regards, Emanuel Antunes Research Assistant (FCT Fellowship - BI) Seismology Laboratory - Complexo Interdisciplinar CERENA, IST, Universidade de Lisboa Av. Rovisco Pais, 1 1049-001 Lisboa, Portugal Email: [email protected]