Hi,

Could you please review these small metadata changes for the event tracing framework:

- Promotion Failed -> objectCount has the datatype BYTES64, which implies that it is a size. It is not, and the type should be an unsigned long.

- Thread Park, Java Monitor Enter and Java Monitor wait should have relational ids, so it's possible to see that the information is related ("java/monitor/address")

- The field "caller" in ExecuteVMOperation should not have a TO field but a FROM field, indicating from which thread the "transition" came from.

The reason the review for 8007150 is handled seperately is because it modifies the structure of the data, while these changes are strictly cosmetical.

http://cr.openjdk.java.net/~egahlin/8008391_1/

Thanks