For interpretation/calibration of the accelerometer values please refer to the Shimmer 9DOF calibration application and associated user manual available for download from www.shimmer-research.com.
Best Regards, Karol From: [email protected] [mailto:[email protected]] On Behalf Of Maxim Michel Sent: 19 May 2012 14:25 To: [email protected] Subject: [Shimmer-users] Raw Shimmer data What does the raw data obtained by the accelerometer (value around 2000) represent exactly? Are these the amplitudes in mV which can be converted into G-forces? I've read in the accelerometer datasheet every 800mV represents 1G at a measuring range of 1.5G. Is this the correct interpretation? Thanks
_______________________________________________ Shimmer-users mailing list [email protected] https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users