Dear Sir or Madam,

I am using the TinyOS to programming the firmware of a Shimmer-sensor version 2. I want to use the Accelerometer and the ECG with one senser and analyse the receive data.

The configuration of this isn't a problem a successfully configured the shimmerAnalogSetup interface, the timer to call the shimmerAnalogSetup.triggerConversion command, which fire the event DMA0.transferDone, when new data are available so that i can call DMA0.repeatTransfer to store the new data. This setup based on the SimpleAccel example under https://github.com/ShimmerResearch/tinyos-shimmer or under tinyos-2.x-contrib.

My problem is that when I receive a new value I have no information, if the new value are received by the Accelerometer or by the ECG. If there are any way to get the information, because I want to make different analyses on the values , this is why I need the information.

Yours faithfully
Mirko Lelansky
_______________________________________________
Shimmer-users mailing list
[email protected]