Oh. I don't know anything about it, unfortunately. But maybe siesta writes
the EIG files at each step; however, since they have the same name, what
remains is the last one. Maybe hacking a bit into the code you can
discover what is the case, and maybe modify the code so as to get what you
need.

Marcos


> Hi Marcos,
>     Thank you very much for the response. I am sorry about the confusion
> with the question, the question is realy how to write out the
> .EIG file for each geometry relaxation step. For the relax calculation,
> SIESTA only write out the .EIG after the relaxation finished, which is
> corresponding to the eigenvalues for the last relaxation step. I was
> wondering whether SIESTA could write out the .EIG for each
> geometry relaxation step, instead of only for the last relaxation step.
> Thank you.
>
> ________________________________
>
> From: Siesta, Self-Consistent DFT LCAO program, http://www.uam.es/siesta
> on behalf of Marcos Verissimo Alves
> Sent: Fri 2007-1-19 9:14
> To: [email protected]
> Subject: Re: [SIESTA-L] How to write out the .EIG file during Phonon mode
> calculation
>
>
>
> No... Mainly because:
>
> 1) EIG files have electronic eigenvalues, not phonon ones, and
>
> 2) what is being calculated during a siesta phonon run is the force
> constants matrix, which will later be diagonalized using the VIBRATOR
> utility and only then, you will have your eigenvalues (phonon frequencies)
> and eigenmodes (phonon vibration modes)
>
> If you are interested in the eigenvalue for a specific eigenmode which you
> already know beforehand, then you can simply do a frozen-phonon
> calculation (check the literature for that), which might be cheaper than
> the full phonon displacements calculations, depending on the system.
>
> Best regards,
>
> Marcos
>
>
>
>> Dear All,
>>     For the Phonon mode calculation, the force constant and phonon mode
>> are calculated by displace each atom in x,y,z direction by MD.FCDispl,
>> there are each .EIG associated with each displacement, however, SIESTA
>> only write out the .EIG file at the end of the calculation, which
>> means it only write out the .EIG for the last displacement. I was
>> wondering that is there any way to write out the .EIG associate each
>> atom displacement during the calculation, instead of only writing out
>> the .EIG for the last dispalcement?
>>     Thank you very much.
>>
>>
>>
>> Ning
>>
>> Uconn
>>
>>
>
>
> --
> Dr. Marcos Verissimo Alves
> Post-Doctoral Fellow
> Condensed Matter and Statistical Physics Sector
> International Centre for Theoretical Physics
> Trieste, Italy
>
> --------
>
> I have become so addicted to vi that I try to exit OpenOffice by typing
> :wq!
>


-- 
Dr. Marcos Verissimo Alves
Post-Doctoral Fellow
Condensed Matter and Statistical Physics Sector
International Centre for Theoretical Physics
Trieste, Italy

--------

I have become so addicted to vi that I try to exit OpenOffice by typing :wq!

Reply via email to