Muchas gracias, Jose! One less thing to worry about on exploration studies (although I have already performed them - it'll save me the work of analyzing all the data, though :) )...
Marcos On Wed, Jan 13, 2010 at 8:53 PM, Jose A. Torres <jose.torres.alo...@uam.es> wrote: > Dear Marcos: > > I have confirmed with the developer of that > part (Daniel Sanchez) and his answer is: > > Yes, the same Ueff will give the same final > results. The current implementation follows > the work of Dudarev et. al. The plan is to > change it for a more rigorous implementation > in a future, though. > > Yours, > > -- > Jose A. Torres, Ph.D. > Manager of the SIESTA Software > tel: +34 914973805 > > from Marcos Veríssimo Alves <marcos.verissimo.al...@gmail.com> > reply-to siesta-l@uam.es > to siesta-l@uam.es > date Thu, Jan 7, 2010 at 4:21 PM > subject [SIESTA-L] Doubt on LDA+U > > Hi all, > > I have a doubt on the LDA+U implementation in siesta, more > specifically on the definition of U and J. > > The siesta LDA+U manual states that "although the input allows to > define independent values of the U and J parameters for each atomic > shell, in the actual calculation the two parameters are combined to > produce an effective Coulomb repulsion U_{eff}=U-J. U_{eff} is the > parameter actually used in the calculation for the time being.". Now, > does that really mean what it seems to imply, namely that any > combination of U and J that produces a given U_{eff} will give me the > same final results? For example, if I want my U_{eff} to be 1.0 eV, > then U=0.6, J=0.4 and U=1.4 and J=-0.4 will give me the same final > results? > > Cheers, > > Marcos > > -- > >