Dear Michael,

Siesta has converted the units of electric field from V/Ang (your input) to 
atomic units (Ry/Bohr/e).
Simply double-check that this corresponds to the same value.

Regards, Ulrich.

----- Original Message -----
From: Michael Shin
[mailto:[email protected]]
To:  Self-Consistent DFT LCAO program        
      http://www.uam.es/siestaSiesta [mailto:[email protected]]
Sent: Sun, 20
May 2012 10:31:30 +0200
Subject: Re: [SIESTA-L] External  E field


> All,
> Reproducing some SrTiO3 data, and I used the following option in .fdf file
> ExternalElectricFieldinBulk  .true.
> %block ExternalElectricField
>   0.000  0.000  0.010  V/Ang
> %endblock ExternalElectricField
>  
> Then I got the following error.
>  
> efield: WARNING: Non zero bulk electric field.
> efield: Input field (Ry/Bohr/e) =    0.000000    0.000000   
> 0.000389
> efield: Orthogonalized field    =    0.000000    0.000000   
> 0.000000
>  
> Can any one let us know that how to cure this problem.
>  

---