Dear Dr. Fthenakis

Thank you very much for your helpful guidance,
Best wishes,
Nadia

On Sun, Jul 26, 2015 at 12:25 PM, <fthe...@iesl.forth.gr> wrote:

> Nadia
> you are not right. A denser k-point sampling COULD be used, but it is not
> necessary. In the 2-dimensional case you have the E(k_x,k_y,k_z=0)
> function for the energy, instead of the more general 3-dimansional
> E(k_x,k_y,k_z). Therefore, the accuracy of the E(k) expression would be
> the same. Just ensure that if you have a denser k-points sampling, DOS
> converges.
>
> Best
> Zacharias Fthenakis
>
> > Dear Dr. Papior,
> >
> > Since my system is a slab, so the scattering occurs in two dimensions
> (the
> > transport direction and also the transverse direction), According to two
> > directions, I think that denser k point sampling along two directions
> must
> > be used to calculate the transmission. Am I right?
> >
> > Thanks in advance,
> >
> > Best regards,
> > Nadia Salami
> >
> > On Sun, Jul 26, 2015 at 11:53 AM, Nadia Salami <nadiasala...@gmail.com>
> > wrote:
> >
> >> Dear Dr. Papior,
> >>
> >> Since my system is a slab, so the scattering occurs in two dimensions
> >> (the
> >> transport direction and also the transverse direction), According to two
> >> directions, I think that denser k point sampling along two directions
> >> must
> >> be used. Am I right?
> >>
> >> Thanks in advance,
> >>
> >> Best regards,
> >>
> >> Nadia Salami
> >>
> >> On Sat, Jul 25, 2015 at 11:46 AM, Nick Papior <nickpap...@gmail.com>
> >> wrote:
> >>
> >>>
> >>>
> >>> 2015-07-25 6:55 GMT+00:00 Nadia Salami <nadiasala...@gmail.com>:
> >>>
> >>>> Dear Transiesta users,
> >>>>
> >>>> I don’t know how to determine correct k point sampling for the
> >>>> Transiesta as well as Tbtrans calculations.
> >>>>
> >>> You converge using the same principles as standard DFT, for transport
> >>> calculations however, you converge the averaged transmission.
> >>>
> >>>> In details, I have determined k-point sampling for the electrode of my
> >>>> system from the energy convergence test, that leads to the following
> >>>> sampling
> >>>>
> >>>> %block kgrid_Monkhorst_Pack
> >>>>
> >>>>  1    0    0    0.0
> >>>>
> >>>>  0    2    0    0.0
> >>>>
> >>>>  0    0   4    0.0
> >>>>
> >>>> %endblock kgrid_Monkhorst_Pack
> >>>>
> >>>>
> >>>>
> >>>> Must the k grid along the transport direction (i.e. kz) be increased
> >>>> to
> >>>> simulate the semi-infinite lead (electrode)?
> >>>>
> >>> I would always use as many k-points in the z-direction as you can (the
> >>> more k-points, the better description of the self-energy you get).
> >>> I typically use 100, if that proves too much, I try with 50.
> >>>
> >>>> Moreover I know that, the denser k-point sampling must be used to
> >>>> calculate the transmission using Tbtrans utility. Must kx and ky be
> >>>> increased? For Tbtrans calculation or both of Transiesta and Tbtrans
> >>>> calculations? (Also I know that kz only is utilized to calculate
> >>>> siesta
> >>>> calculation in the scattering region.)
> >>>>
> >>>  Transiesta calculates the density, tbtrans calculates the transport.
> >>>
> >>>> Finally, how to converge the k-point sampling for the transmission
> >>>> calculation?
> >>>>
> >>>> It will be highly appreciated your comments and guidances.
> >>>>
> >>>> Thanks in advance,
> >>>>
> >>>> Best regards,
> >>>>
> >>>> Nadia Salami
> >>>>
> >>>>
> >>>>
> >>>
> >>>
> >>>
> >>> --
> >>> Kind regards Nick
> >>>
> >>
> >>
> >
>
>
> *********************************************************
> Dr Zacharias G. Fthenakis
> Research Associate
> Institute of Electronic Structure and Laser (I.E.S.L.)
> Foundation for Research and Technology Hellas (FO.R.T.H.)
> Vassilika Vouton P.O. Box 1527 71003 Heraklion Crete Greece
> Phone +30 2810 391824
> FAX   +30 2810 391305
> webpage: http://esperia.iesl.forth.gr/~fthenak
> **********************************************************
>
>

Responder a