Dear Nick thank you very much I On Tue, Oct 27, 2015 at 12:19 PM, Nick Papior <[email protected]> wrote:
> The right electrode atoms are not equal to the equivalent electrode atoms > found in the device region. > Hence, you have an inconsistency in your setup. > Check that your atomic basis sets are the same in electrode and device > calculation. > > > 2015-10-27 4:37 GMT+01:00 azar ostovan <[email protected]>: > >> Dear transiesta users >> >> When I run transiesta calculation, facing with this error >> >> Got RIGHT Electrode GF >> >> Done >> >> ERROR: lastoR,NGR2 0 13 26 >> 39 52 57 62 75 88 >> 101 114 127 140 153 166 >> 171 176 189 202 215 228 >> 241 254 267 280 285 290 >> 303 316 329 342 355 368 >> 381 394 399 404 417 430 >> 443 456 469 482 495 508 >> 513 518 531 544 557 570 65 >> >> ERROR: Unexpected no. orbs. in R elec. >> >> What is the wrong with my fdf. >> >> Please help me >> >> Kind regards >> Azar ostovan >> > > > > -- > Kind regards Nick >