Dear All,

I used npr algorithm for graphite cell, but cell explodes

# MgCO3 in primitive cell. SZ. Nose-Parrinello-Rahman.
#
SystemName MgCo3 R-3c -- SZ, 50 R -- NPR at 10 Gpa, 500K
SystemLabel md_npr
NumberOfSpecies 1
NumberOfAtoms       12
%block ChemicalSpeciesLabel
1  6 C
%endblock ChemicalSpeciesLabel

PAO.BasisSize DZP
PAO.EnergyShift 65 meV

# Rhombohedral primitive cell
# (HEX 3-fold cell had A=4.635 and C=15.023, so alpha=48.179 degrees
#  and a=5.67783 Ang)

LatticeConstant 1.0 Ang
%block LatticeParameters
2.60164384 2.60164384 22.07568000 90.00000 90.00000 90.00000
%endblock LatticeParameters

AtomicCoordinatesFormat    Fractional

%block AtomicCoordinatesAndAtomicSpecies
0.00000000 0.00000000 0.64583300 1
0.50000000 0.50000000 0.72916700 1
0.00000000 0.50000000 0.68750000 1
0.50000000 0.00000000 0.60416700 1
0.00000000 0.00000000 0.47916700 1
0.50000000 0.50000000 0.56250000 1
0.00000000 0.50000000 0.52083300 1
0.50000000 0.00000000 0.43750000 1
0.00000000 0.00000000 0.31250000 1
0.50000000 0.50000000 0.39583300 1
0.00000000 0.50000000 0.35416700 1
0.50000000 0.00000000 0.27083300 1
%endblock AtomicCoordinatesAndAtomicSpecies

#%block GeometryConstraints
# stress 3 4 5
# position  12 0.0  0.0  1.0
#%endblock GeometryConstraints

MeshCutoff             200 Ry
DM.NumberBroyden       4
DM.UseSaveDM           T
DM.MixingWeight 0.05
DM.Tolerance 1.d-4
DM.NumberPulay 8
MaxSCFIterations 400

WriteCoorStep      .true.
WriteForces        .true.
WriteMDHistory     .true.
WriteCoorXmol yes
UseSaveData           .true.
SaveRho                 .true.       #
MD.UseSaveXV       T

MD.TypeOfRun         NoseParrinelloRahman
MD.Target-pressure   0.000101325 GPa
MD.Target-temperature   1023 K #as in Lammps paper
MD.Initial-temperature   1023 K #as in Lammps paper
MD.Initial.Time.Step      1
MD.Final.Time.Step        10000
MD.Length.Time.Step       0.3 fs

=============================================================
1) do i need to use anneal to avoid exploding
2) does the gamma point not enough, or cell too small
3) what about pressure - should i use 1 atm pressure for the object heating
to some temperature? which pressure should I use for the slab?

-- 
Best wishes,
Maxim Arsent'ev, Ph.D. (Chemistry)
Laboratory of research of nanostructures
Institute of Silicate Chemistry of RAS
-- 
SIESTA is supported by the Spanish Research Agency (AEI) and by the European 
H2020 MaX Centre of Excellence (http://www.max-centre.eu/)