Hi, 

Your 'slab' is just three layers thick... that is not nearly enough to have a 
good representation of 
a "bulk" region in the center and a "surface" region. 

After you fix that, you probably need to process the .VH file and obtain a 
potential profile along 
z to check that you reach a flat region in the vacuum. 

Alberto 

----- El 15 de Marzo de 2023, a las 11:41, yh46 <y...@rice.edu> escribió: 

| Hello Dear SIESTA Users,
| I am trying to do a work function calculation of Au 111 surface. The
| work function I get if 3.5 eV, which is quite different from
| experimental results ~ 5.26eV, or Quantum Espresso Result(Physical
| Review B, 2009, 80(23): 235407) ~ 5.15eV, or VASP result from my
| own~4.8eV. I understand that they are different codes, however the
| results are too different. I am wondering if there is anything wrong
| with my input file or the pseudo potential file that I use? I have
| attached the input files. Thank you very much!

| Best,
| Yuefei

| --
| Yuefei Huang
| Graduate Student
| Department of Material Science and NanoEngineering
| Rice University
| email: yuefei.hu...@rice.edu
| phone: +1-832-499-9169

| --
| SIESTA is supported by the Spanish Research Agency (AEI) and by the European
| H2020 MaX Centre of Excellence
| 