Hi, On Tue, Apr 10, 2018 at 03:35:28PM +0200, Jörg wrote: > Hello, > > this patch is meant to fix the error "Default Voltage_Threshold" is not > programmed into the HW. > > Described is the behavior in this bug > https://sigrok.org/bugzilla/show_bug.cgi?id=1149
Your patch below is merged, thanks! (btw, it's a bit nicer to clone the repo, commit your changes and then export a patch via "git format-patch HEAD~1" or similar; that way your name + email + commit message will be properly visible in the commit history; or you can just use github and let us know about pull requests as needed). > Do not close Bug-ID 1149, because the actual function for Pulseview has > not yet been solved! These are two separate issues, yeah. I added some more info to #1149, probably a floating-point related issue in PulseView. Can you confirm that (with your patch) sigrok-cli works fine now and shows no issues anymore? Cheers, Uwe. -- http://hermann-uwe.de | http://randomprojects.org | http://sigrok.org ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel