Hi,

On Tue, Apr 10, 2018 at 03:35:28PM +0200, Jörg wrote:
> Hello,
> 
> this patch is meant to fix the error "Default Voltage_Threshold" is not
> programmed into the HW.
> 
> Described is the behavior in this bug
> https://sigrok.org/bugzilla/show_bug.cgi?id=1149

Your patch below is merged, thanks! (btw, it's a bit nicer to clone the repo,
commit your changes and then export a patch via "git format-patch HEAD~1"
or similar; that way your name + email + commit message will be properly
visible in the commit history; or you can just use github and let us
know about pull requests as needed).


> Do not close Bug-ID 1149, because the actual function for Pulseview has
> not yet been solved!

These are two separate issues, yeah. I added some more info to #1149,
probably a floating-point related issue in PulseView.

Can you confirm that (with your patch) sigrok-cli works fine now and
shows no issues anymore?


Cheers, Uwe.
-- 