Hi Bianca,

>    However when I add the PWM protocol option I always retrieve the PWM
>    data of channel 0
>
>    sigrok-cli -d fx2lafw:conn=1.11 --config samplerate=100000 --samples
>    10000 -C D0 -P pwm
>
>    sigrok-cli -d fx2lafw:conn=1.11 --config samplerate=100000 --samples
>    10000 -C D1 -P pwm

You need to tell the protocol decoder which channel to use, so something
like this:

sigrok-cli -d fx2lafw:conn=1.11 --config samplerate=100000 --samples 10000 -C 
D1 -P pwm:data=D1

Christian.



_______________________________________________
sigrok-devel mailing list
sigrok-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sigrok-devel

Reply via email to