In our recent researches evaluating this technology and, consequently, in
searching for possible "process" improvements/modifications which might
facilitate the "lay person" an opportunity for a DIY methodology achievable
in a home environment---we did achieve some notable progress.
First, a brief summary of our exploratory activity. Our literature searches
revealed several companies actively exhibiting valid capability in this area
(LET).
Typical, and demonstrably capable, is a company named MICROTEK.
Microteklabs.com
Helpful information is available here.
One fact became obvious, early on, to wit: The truly striking feature of LET
was a NATURALLY-occurring characteristic...... and not a man-made process,
that was driving this encapsulation process. That is, this process is a
function of an automatic, "natural tendency" of certain substances (e.g.
phospholipids in this case) to form tiny vacoules or
bubbles---called liposomes----when in a aqueous solution under certain
conditions. "
The keystone activity is that these liposomes automatically fill themselves
with whatever aqueous solution they were in----before they were formed.
"This type of bubble, called a membrane, forms a protective barrier around
virtually every cell in the human body."
Livon Labs has perfected a process which employs a high-pressure (1700
p.s.i.) discharge system which directs a liquid stream against a forming
plate. The high impact forces the phospholipids (soy lecithin in this case)
to form liposomes----so small they require an electrom microscope for
viewing. This technology does not create the LET activity....it just
enhances it. In our personal researches we have determined the key to
exploiting the LET phenomenon appeared to be Livon's application of intense
force in their mixing methodology.
Enter the "enlightening" moment. Searching for a method of achieving
liposomal encapsulation, it occurred to us to explore ultrasonic stimulation
as an option. It worked...maybe not quite as well as Livon's "high tech"
brute force approach...but about 70% as well. Plenty efficient for our
purposes.
Our vitamin "C" liposomal encapsulation protocol is as follows:
Using a small (2 cup) Ultrasonic cleaner, (Item #03305, obtainable from
Harbor Freight @ about $30.00), we performed the following:
1. Dissolved 3 level tablespoons of soy lecithin in 1 cup of water
(preferably distilled).
2. Dissolved 1 level tablespoon of ascorbic acid powder (Vit. "C") in 1/2
cup
of water.
3. Poured both solutions together in the ultrasonic cleaner bowl and turned
the unit on. Using a plastic straw (leaving the top of the cleaner opened),
gently, slowly, stirred the contents. Note: The cleaner will, automatically,
self-stop about every 2 minutes. Just push ON button to continue. Repeat for
a total of 3 series (6 minutes). By that time the entire solution should be
blended into a cloudy, homogeneous,
milk-like mixture. The LET solution is now formed.
4. This protocol furnishes about 12 grams (12000mg.) of vitamin C product.
At 70% encapsulation efficiency, 8400 mg would be of the LET type. This
solution will keep, acceptably, at room temperature for 3 to 4 days.
Refrigerated, it will keep much longer. We use it so fast around our
place...there isn't enough left to be concerned over storage. The
"homogenizing effect" is so powerful that after 3 days at room temperature,
no precipitation or solution separation appears evident. This type of
sequestered vitamin "C" has demonstrated to be, at least 5 times more
effective (per volumetric measure) than any other form of orally-ingested
vitamin "c"....that we have tested. Additionally, it appears to be even more
rapid in tissue-bed availability----than IV applications. An astounding
revelation....to us. We estimate the DIY researcher can produce the active
LET portion of this solution for 15 cents per gram....as against about $1.00
per gram from commerci! al sources.
It is my hope that this, limited, explanation of our activities in this
area,
is of some value to our do-it-yourself health-maintenance researchers. In
any event, this protocol has demonstrated to be n on-toxic and most helpful
to OUR RESEARCHES.
Sincerely, Brooks Bradley.
p.s. A larger, more powerful, ultrasonic cleaner is now available at Harbor
Freight. Item number 91593. 2+ liters, for about $60.00. Both units have
performed quite well for us. Almost as well as our $500.00 lead zirconate
titanate, research grade, unit.





On Thu, Aug 20, 2009 at 12:41 AM, Jim Holmes <gooogleis...@gmail.com> wrote:

> Hello All,
>
> I missed Brook;s post on how to make the stuff.  Will someone please direct
> me?
>
> Jim
>
>