I notice the solution labelled 20ppm has a conductivity reading of 160uS, is that a typo?
Ivan. -----Original Message----- From: Connie [mailto:[email protected]] Sent: Sunday, 2 December 2001 12:05 p.m. To: silver- list Subject: CS>Robey Mark 4 generator/test results I requested Ole Bob test samples from the Robey Mark IV generator a friend uses. I believe this gives me the right to post his testing results. The addy for this generator boasts 20-80 ppm in 10 minutes, my friend says it does have an automatic shut off. Sample labeled 80 PPM; Conductivity = 18 uS/cc; pH = 6.41; Strong T.E.; Ag = 12.98 PPM; crystal clear. Sample labeled 60 PPM; Conductivity = 15 uS/cc; pH = 6.27; Strong T.E.; Ag = 15.4 PPM; crystal clear. Sample labeled 40 PPM; Conductivity = 10 uS/cc; pH = 5.70; Strong T.E.; Ag = 4.62 PPM; crystal clear. Sample labeled 20 PPM; Conductivity = 160 uS/cc; pH = 7.30; Medium T.E.; Ag = 0.55 PPM; very slight yellow. Sincerely, "Ole Bob" -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] Silver-list archive: http://escribe.com/health/thesilverlist/index.html List maintainer: Mike Devour <[email protected]>