The bubbler method is best.  You can run it a bit longer to get a heavier
TE.
 Coffee pot hot plates are way too hot.
 With the bubbler, you shouldn't need to heat at all.
 Heating does 2 things
1] increases intitial conductivity [already done by seeding]
2] induces thermal stirring currents as the water cools...or, if
contiuously heated, induces stiring currents as it heats [all done with the
bubbler.

Exceeding 120 deg F is likely to result in a yellow CS, but bubbling is
probably keeping the temperature down.
 You don't need the hot plate.
 Using cooler water tends to increase the TE. [particle to ion ratio]

Ken



At 12:26 PM 8/20/02 -0400, you wrote:
>
>I have been brewing different ways to see which way makes the 'best' CS
>solution (for me).  I would like some input from the 'experts' here who
>have made CS themselves.
>
>I am using 16 oz. distilled water, 3 nine-volts (which I change to 2
>nine-volts half way thru to lower the current), 2 - .9999 silver wires, a
>coffee pot heat plate, and a fish bubbler (plus alligator clips, etc....).
>I'm spiking the solution with premade CS (approx. 1/4 of the batch) to
>raise initial conductivity of the water.  I'm brewing without the bubbler
>until I see the yellow wisps start, then I start the bubbler and brew for
>another hour, stopping 1/2 way thru to clean the silver wires and
>disconnect one of the batteries (to lower the current flow).
>
>My main question is:
>
>I notice that when I make CS using the above method the solution is clear.
>Is the CS solution I'm making more dissolved silver than colloidal silver?
>Does the bubbler make the silver dissolve?  I hardly have any Tyndall
>effect at all; very very light.  And the taste is also light, but still
>there.
>
>I checked to make sure there was current flowing.  I don't have a fancy
>multimeter, just a little cheepy one.  But it does show that there is
>current flowing to the silver wires.
>
>When I do the same as above but DO NOT use the bubbler, the solution is
>yellow and the silver wires must be wiped off during the brewing (I wipe
>them off when I'm disconnecting one of the batteries - about 30 minutes
>into the brew).  The solution is much different/stronger in Tyndall, taste,
>color, etc.   than the bubbler version.
>
>Which way is the "best?"
>
>Thanks
>Christine
>
>_____________________________________
>
>Christina McCauley
>Kaye Scholer LLP
>901 15th Street, N.W.
>Washington, DC  20005
>
>Telephone:  202-682-3556
>Fax:  202-682-3593
>_____________________________________
>
>This message may contain confidential and/or legally privileged information
>from the law firm Kaye Scholer LLP.  If delivered to anyone other than the
>intended recipient, please notify the sender immediately by return email or
>by telephone (202-682-3500) and delete the message, along with any
>attachments, from your computer.  Thank you.
>
>
>--
>The silver-list is a moderated forum for discussion of colloidal silver.
>
>Instructions for unsubscribing may be found at: http://silverlist.org
>
>To post, address your message to: [email protected]
>
>Silver-list archive: http://escribe.com/health/thesilverlist/index.html
>
>List maintainer: Mike Devour <[email protected]>
>
>