Re: CS>high ppm CS experiment, was Re: CS>CS site
From: sol
Date: Wed, 23 Mar 2005 19:44:13
http://escribe.com/health/thesilverlist/m78777.html

  > Mike,

  > I have  in previous years run a couple of other  high  ppm batches
  > (all were pints, as the one below was), but don't have  records on
  > those.

  > It does seem to me that going above 15 or 20 ppm introduces  a lot
  > more variables into the process, or perhaps it is  just inherently
  > more susceptible to minute variables or water or  air contaminants
  > with larger  batch sizes. The particular batch below  is  the only
  > one of about 3 high ppm batches I've made that turned out clear.

  > What do you mean by "poison the electrodes" ?

  > I will  be  doing some more batches of high ppm, and  will  try to
  > keep better notes. I am writing to David too. And can post results
  > either to the list or privately.

  > sol

  Thanks very much for your help, sol. Yes, I found getting to 20uS is
  reasonably easy, then it seems to hit a brick wall.  Every increment
  in performance becomes twice as difficult.

  The water has a lot to do with it, but I have no idea what  it could
  be. I was sure David's results with demineralized water  would prove
  to be  in  error, but he easily passed every test I  could  throw at
  him. His PWT reading of 53uS was astounding to me.

  Also note he uses magnetic stirring, and I believe you have thermal.
  This shows  the high PWT readings are possible under  very different
  conditions, so the process may turn out to be quite robust.

  Some time  ago, I reported an extremely hard and very  black coating
  on the  electrodes  that  would  not  come  off  even  when  I tried
  scraping. The  WalMart  dw  suddenly  changed,  and  the  cs started
  behaving very strange. This was an attempt to kill mold spores in my
  blankets, and  I  was adding H2O2 to convert any oxides  to  ions to
  gain a  bit  more strength. When I added the H2O2, the  4  litre jar
  instantly turned  brilliant  yellow,  then   white.  It  was  like a
  miniature atomic  explosion.  It  took a lot  of  H2O2  to  turn the
  solution clear again.

  After I  found better dw, I noticed the hard coating on  the cathode
  starting to disappear. It took 7 or 8 brews, swapping the electrodes
  each time,  to  finally remove the coating. That's what  I  meant by
  "poisoning" the electrodes.

  The topic of high uS may be of great help to others. I made my first
  batch of 44.9uS cs on March 4. Three weeks later, on March 20, about
  half the  symptoms from mold toxins have disappeared.  I  was taking
  20uS cs  for years with no effect, but increasing  the  strength has
  really made a difference.

  My new  cs  generator works, but it uses  fairly  high  voltage that
  could be  lethal,  and  would   be   difficult  for  many  people to
  duplicate. It  would  be wonderful to find  a  simpler  process that
  anyone could use, and even better if it utilized a readily available
  and well known product.

  Please post  results to the list so all those who may  be interested
  can view them. 

Best Wishes,

Mike Monett


--
The Silver List is a moderated forum for discussing Colloidal Silver.

Instructions for unsubscribing are posted at: http://silverlist.org