Dear Awei,

Please use the following command after building Flexus (e.g., "make UP.Trace").

$SIMICS/scripts/start-simics  -no-module-cache \
 -P modelbuilder -sign-module \
 $FLEXUS_ROOT/simulators/UP.Trace/libflexus_UP.Trace_v9_iface_gcc.so

Substitute your path to simics for $SIMICS and the flexus root directory for 
$FLEXUS_ROOT.

Regards,
Pejman
________________________________________
From: w x [[email protected]]
Sent: Wednesday, June 29, 2011 2:31 PM
To: [email protected]
Subject: Simics Model Builder License Error in Flexus

Hi,
 I am trying to run the FLEXUS 4.0 Test application but unable to run due to 
the following error when executing the step :

 run_job \
   -postprocess "SCRIPTS_ROOT/postprocess_ckptgen.sh flexpoint 24 test_app" \
   -cfg trace -run flexpoint -local -ckpt-gen UP.Trace flexus_test_app_x86

==================================================================================

*** builder: Failed to checkout feature
For further information, refer to the FLEXlm End User Manual,
available at "www.macrovision.com<http://www.macrovision.com>".
Error loading module 'flexus-UP.Trace-x86-iface-gcc': License Error: module
not signed. Module 'flexus-UP.Trace-x86-iface-gcc' not loaded.
 Simics Model Builder license needed to sign modules.


[start.simics:5] the command did not complete properly; interrupting script
ERROR: Invalid return code from Simics: 1
</opt/flexus-4.0/result/basedir/trace-UP.Trace-28Jun11-220056/flexus_test_app_x86/000_000


Reply via email to