Hi Sergio,

I don't think I realized you were using x86 as a target.  We don't  
decode non-memory instructions for x86, so that's why the opcode is  
always zero.  See the following mail message from our archive for some  
possible workarounds (thanks to Vaggelis for pointing this out to me):

https://sos.ece.cmu.edu/pipermail/simflex/2008-October/000436.html

As for your second question, this is again a limitation of our x86  
models.  In our papers we use a detailed, cycle accurate processor  
model for SPARC architectures (e.g., CMPFlex.OoO or DSMFlex.OoO).   
There we can vary the details of the microarchitecture to model very  
aggressive out-of-order cores, lean in-order cores, or even multi- 
threaded cores.  Changing the target processor in Simics will not get  
you this effect.  You could throttle instruction retirement to get a  
very simple mix of faster versus slower processors, though.  But, as  
noted above, this is tough if you want to examine the opcode when  
making that decision.

Hope this helps,
Brian

On Apr 15, 2009, at 12:17 PM, Sergio Tota wrote:

> Hi Brian,
>
> I'm having some problems on getting the opcode of the fetched  
> instruction. The opcode I get is always zero.
> Which part of flexus do you suggest me to tweak?
>
> Just another question. In some papers flexus was adopted to perform  
> multiprocessor simulations using different cores (small,medium and  
> monolithic).
> What I don't get exactly is how it would be possible to use flexus  
> in this way varying the type of processors. I simply use the CMPFlex- 
> x86 simulator
> and I'm wondering how I can change the "target" processor to be used  
> in the simulation.
> I guess that I can do that changing the simics configuration like  
> "test.simics" working with the "target" (add-directory "%simics%/ 
> targets/x86-440bx").
> Is that correct?
>
> Thanks.
>
> Sergio
>
> Brian Gold wrote:
>
>> Oops, that should have been:
>>
>>> unsigned long opcode = theROB.front()->instruction().opcode();
>>
>>
>> I haven't tried this, so you may have to tweak it a bit.
>>
>> - Brian
>>
>> On Jan 27, 2009, at 2:36 PM, Brian Gold wrote:
>>
>>> Hi Sergio,
>>>
>>> You can do this in doCommit().  To get the opcode, try:
>>>
>>> unsigned long opcode = theROB.front()->instruction()->opcode();
>>>
>>> In a multiprocessor simulation, each core gets its own Execute   
>>> module, so yes, you can selectively control the behavior of each   
>>> processor instance.
>>>
>>> Let us know if you have any other questions.
>>>
>>> - Brian
>>>
>>> On Jan 27, 2009, at 12:24 PM, Sergio Tota wrote:
>>>
>>>> Dear Brian,
>>>>
>>>> Thanks for your help.
>>>>
>>>> I succeeded to add a wait-state to the doCommit() function.
>>>> I'm still not sure where to inspect the opcode to decide if wait-  
>>>> state should be enabled though.
>>>> Should I inspect it in the doCommit() or somewhere else like  
>>>> inside  "SimicsTracer.hpp" around line 588?
>>>>
>>>> Another question I have is about performing a multiprocessor   
>>>> simulation using this wait-state approach.
>>>> Can I selectively control the behaviour of every processor  
>>>> instance  to decide if a given instruction should be performed in  
>>>> one cycle  or two cycles?
>>>>
>>>> Thanks.
>>>>
>>>> Sergio
>>>>
>>>>
>>>> Brian Gold wrote:
>>>>
>>>>> Hi Sergio,
>>>>>
>>>>> I recommend you look at the Execute module (components/Execute/   
>>>>> ExecuteImpl.cpp).  Look at the doCommit() function around line   
>>>>> 866.   This function gets called every cycle, so you can simply   
>>>>> insert wait  states after inspecting the opcode accordingly.   
>>>>> You  can alternatively  stall the dispatch() side of the  
>>>>> pipeline in  the Execute module, but  it may take a little bit  
>>>>> more work.  Let  us know if you have further  questions.
>>>>>
>>>>> - Brian
>>>>>
>>>>>
>>>>>
>>>>> On Dec 12, 2008, at 12:00 PM, Sergio Tota wrote:
>>>>>
>>>>>> Hi,
>>>>>>
>>>>>> I'm quite new to Simics & Flexus so probably some of my   
>>>>>> assumptions  are wrong.
>>>>>> What I'm trying to do is to make some instructions multi-cycle.
>>>>>> For what I got Flexus increases the cycles-counter every new    
>>>>>> instruction fetch.
>>>>>>
>>>>>> What I would like to do is to analyze every instruction and    
>>>>>> selectively decide if the given instruction
>>>>>> is one cycle (cycles-counter= cycles-counter +1) or multi- 
>>>>>> cycle   (cycles-counter= cycles-counter +2).
>>>>>> (For now my multi-cycle is 2 c.c. instead of normal 1 c.c.)
>>>>>>
>>>>>> To implement this behavior I can see two main steps:
>>>>>> 1)Analyze the op-code every instruction fetch
>>>>>> 2)Selectively increase Flexus cycles-counter of 1 or 2.
>>>>>>
>>>>>> For both the points I think that I have to work at the    
>>>>>> "SimicsTracer.hpp",
>>>>>> in the Instruction Fetch section starting from line 588.
>>>>>>
>>>>>> What I would do for Point-1 is to use the   
>>>>>> "SIM_read_phys_memory()"  function
>>>>>> to inspect the opcode at every instruction fetch in order to   
>>>>>> decide  if the given instruction
>>>>>> will be 1-cycle or 2-cycles.
>>>>>> Once I have decided the cycle-length of the instruction I  
>>>>>> would  use  the Flexus function
>>>>>> "theCycleManager->advanceFlexus()" twice instead of only one  
>>>>>> as  it  is in the original code
>>>>>> in case of 2-cycles operations to perform Point-2.
>>>>>>
>>>>>> For what I got, at every instruction fetch this function is   
>>>>>> called  at the very beginning of the code.
>>>>>> I would add a second call to this function every time I detect  
>>>>>> a   particular op-code that I want to make 2-cycles.
>>>>>>
>>>>>> I'm particularly worried about synchronization problems  
>>>>>> between   Flexus and Simics,
>>>>>> especially in case of CMP simulation where more instances of  
>>>>>> the   processor are running.
>>>>>>
>>>>>> Can you give me some advices about what I'm trying to do?
>>>>>>
>>>>>> Thanks.
>>>>>>
>>>>>> Sergio
>>>>>> _______________________________________________
>>>>>> SimFlex mailing list
>>>>>> SimFlex at ece.cmu.edu
>>>>>> https://sos.ece.cmu.edu/mailman/listinfo/simflex
>>>>>> SimFlex web page: http://www.ece.cmu.edu/~simflex
>>>>>
>>>>>
>>>>>
>>>>>
>>>> _______________________________________________
>>>> SimFlex mailing list
>>>> SimFlex at ece.cmu.edu
>>>> https://sos.ece.cmu.edu/mailman/listinfo/simflex
>>>> SimFlex web page: http://www.ece.cmu.edu/~simflex
>>>
>>>
>>> _______________________________________________
>>> SimFlex mailing list
>>> SimFlex at ece.cmu.edu
>>> https://sos.ece.cmu.edu/mailman/listinfo/simflex
>>> SimFlex web page: http://www.ece.cmu.edu/~simflex
>>
>>
>>
>
>
> -- 
> *************************************
> Sergio Tota, PhD
> Dept. of Electronic (VLSI Lab)
> Politecnico di Torino
> Corso Duca degli Abruzzi 24,
> 10129 Torino, ITALY
> Tel. +39 011 564 4004
> Fax: +39 011 564 4099
> *************************************
>

Reply via email to