On Sat, 24 May 2014, Larry Baker wrote:
Fixed! You can download the replacement SIMH2MTD.EXE(_ALPHA)'s from our FTP
site, ftpext.usgs.gov.
Thanks!
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 11:06 PM, Larry Baker wrote:
Well, I think it is my SIMH2MTD converter that is the problem. I padded writes
to a WORD (2-byte) boundary. MTD is expecting padding to a 4-byte boundary --
and it is pickier than TAPELOOK! (I added reading MTD images in TAPELOOK and
then used the same login in SIMH2MTD -- sort of).
I'll get back to you.
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 10:55 PM, Larry Baker wrote:
It turns out the debugging output is written to Fortran unit 3, not to the
terminal (I don't remember why). So it is in a file called FOR003.DAT. You
probably have one too.
The error is the first "DKGET":
---> Enter DKGET ( 1,indx,isize,eof,ierr)
---> 67 = DKGET (fcb(LUN), 1, 2062, F, 67)
Now I have to figure out why.
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 10:41 PM, Larry Baker wrote:
I hacked MTD to allow the NL: device instead of a tape drive. I'm getting the
same error you did:
BAKER TONGA> mtd [-.SIMH2MTD.MTD_TAPE_IMAGES]RSTSE_V10_1_INSTALL_SEP10_1992.MTD
nl:/noappend
MTD -- Begin transfer.
MTD -- Error reading disk file.
Now at least I can figure out why.
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 10:14 PM, Cory Smelosky wrote:
On Fri, 23 May 2014, Larry Baker wrote:
What do you mean by that?
My tape drive appears to be malfunctioning.
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 9:59 PM, Cory Smelosky wrote:
On Fri, 23 May 2014, Larry Baker wrote:
Your command is different -- last time you had /noappend.
Oops. Anyways I narrowed the problem down the tape drive being funny.
Larry Baker
US Geological Survey
650-329-5608
[email protected]
On May 23, 2014, at 8:42 PM, Cory Smelosky wrote:
On Fri, 23 May 2014, Larry Baker wrote:
I uploaded mtd_debug.exe to our ftp site. Rename the original mtd_save.exe,
then rename mtd_debug.exe to mtd.exe and try agin. Maybe that will give us a
clue.
MOYA::CSMELOSKY$ mtd rsts-conv.tap mua0:
MTD -- Begin transfer.
MTD -- Error spacing files.
Different!
Larry Baker
US Geological Survey
650-329-5608
[email protected]
--
Cory Smelosky
http://gewt.net Personal stuff
http://gimme-sympathy.org Projects
--
Cory Smelosky
http://gewt.net Personal stuff
http://gimme-sympathy.org Projects
--
Cory Smelosky
http://gewt.net Personal stuff
http://gimme-sympathy.org Projects
--
Cory Smelosky
http://gewt.net Personal stuff
http://gimme-sympathy.org Projects
_______________________________________________
Simh mailing list
[email protected]
http://mailman.trailing-edge.com/mailman/listinfo/simh