Hi,
Is there a way to use sec feeding variable thresholds to the rules in the
config files?
There are some processes that we are monitoring using the "control chart"
algorithm. This algorithm takes the data in a given time window and
calculates its mean and its upper and lower control limits that indicate
the threshold at which the process output is considered statistically
'unlikely'.
The question is ¿can we use this calculated upper and lower control limits
as thresholds with sec? ¿how can we modify the threshold in a rule without
stopping and restarting sec? ¿is it possible?
thanks in advance.
-------------------------------------------------------------------------