Hi, As per the 12.2.2 section of the RFC 3261 the incoming CSeq should be greater than the stored remote CSeq. It MUST reject it with 500 Server Internal Error.
Regards, Atul -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David Stuart Sent: Friday, March 03, 2006 7:34 PM To: [email protected] Subject: [Sip-implementors] out-of-order requests Hello, Let's say the UAC sends two in-dialog requests, with CSeq 100 and CSeq 101 respectively, but due to some networking issues, the second request arrives before the first- the UAS receives 101, and then 100. What is the proper response to the request with CSeq 100? Dave -- David Stuart, SIPquest Email: dave (at) sipquest (dot) com Phone: 254-8886 x234 Web: http://www.sipquest.com/ Address: 300 - 350 Terry Fox Drive, Kanata Ontario, K2K 2P5 _______________________________________________ Sip-implementors mailing list [email protected] https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors _______________________________________________ Sip-implementors mailing list [email protected] https://lists.cs.columbia.edu/cucslists/listinfo/sip-implementors