Does https://tools.ietf.org/html/rfc3264#section-8.3.1 describe this case, thus it's ok?
23.06.2019, 22:22, "r...@yandex.ru" <r...@yandex.ru>: > Hi everyone > > Is it ok from SIP, SDP perspective changing "c", connection data in > subsequent SIP/183 response. > > For example: > > INVITE ---> > <--- 183, c=IN IP4 1.1.1.1 > <--- 183, c=IN IP4 2.2.2.2 > _______________________________________________ > Sip-implementors mailing list > Sip-implementors@lists.cs.columbia.edu > https://lists.cs.columbia.edu/mailman/listinfo/sip-implementors _______________________________________________ Sip-implementors mailing list Sip-implementors@lists.cs.columbia.edu https://lists.cs.columbia.edu/mailman/listinfo/sip-implementors