thanks,
the email was may be too concise... when I change the cmd to -l 1 -m 2 , the
second call fails - if i try with with -l 10 -m 50, it sets up one call
correctly, then also fails....

my impression - not knowledgeable enough though - is that the repetition of
the same message confuses asterisk somehow...

j.



On Wed, Jul 1, 2009 at 12:35 PM, Mike Ayers <[email protected]> wrote:

> > From: Jean Cérien [mailto:[email protected]]
> > Sent: Tuesday, June 30, 2009 3:05 PM
>
> > When I am running 1 call, 1 simultaneous, everything is fine.
> > When I run 2 calls, 1 simultaneous, eg, 1 after the other, it
> > fails with a message on the * box '  chan_sip.c:1976
> > retrans_pkt: Maximum retries exceeded on transmission sippuac
> > for seqno 1 (Critical Response) and a message received by the
> > client: Status 503: server error
> >
> > here is the cmd line from the client:
> > >sipp -cid_str sippuac -s 123  -d 5000  -sn uac
> > 192.168.1.15:5070  -l 1 -m 1
> >
> > Of course, if i try many simultaneous calls, it fails -
>
>        You have the "-m" flag set to stop after the first call.
>
>
>        HTH,
>
> Mike
>
------------------------------------------------------------------------------
_______________________________________________
Sipp-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/sipp-users

Reply via email to