On Tue, May 17, 2011 at 11:16 AM, mayamatakeshi <[email protected]>wrote:

>
>
> On Tue, May 17, 2011 at 2:37 AM, William King <[email protected]>wrote:
>
>> I'm running the standard uac scenario, but I'm trying to test the voip
>> adapter answering and hanging up the calls. After a hangup sipp
>> complains that it was not expecting the BYE and that it is treated as an
>> error. Where do I configure the BYE expectation?
>>
>
> Hello,
> 1) dump the scenario:
>   sipp -sd uac > uac.xml
> 2) edit the scenario to expect BYE insted of sending it  (you can copy the
> code from the embedded uas scenario "sipp -sd uas > uas.xml")
> 3) use the edited scenario instead of the embedded one:
>   sipp -sn uas.xml ... other parameters ...
>

Sorry, small correction:

3) use the edited scenario instead of the embedded one:
  sipp -sf uas.xml ... other parameters ...



>
> regards,
> takeshi
>
>
------------------------------------------------------------------------------