Woof! On Wed, 12 Nov 2008 17:22:30 -0500, M. Ranganathan <[EMAIL PROTECTED]> wrote:
> What would be the cause for the FreeSWITCH based Auto Attendant > returning 480 Temporarily Unavailable ? Most likely sipXivr isn't running. When FS gets a call to [EMAIL PROTECTED] it's dialplan tells it to use "mod_socket" to create a TCP/IP control socket connection to sipXivr running on port 8084. It that connection cannot be made (e.g. because the process isn't running), FS will generate that error. --Woof! _______________________________________________ sipx-dev mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-dev Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-dev