On Thu, Jul 14, 2011 at 3:19 AM, Eda Ercan <edaer...@gmail.com> wrote:
> I have a case like this: Extension 201 calls ext. 200. In call forwarding > settings of user 200, 200 rings for 20 secs, if no response call is > forwarded to 05371234567 (some mobile number here). > > I am using Audiocodes M800 configured as an unmanaged gateway, and the > gateway is configured with one PSTN line, 2650123. > that's the inbound number or caller id? how would sipxecs even know this number, did you configure this somewhere in the sipxecs ui? if so where? > In the cdr of this call, callee route contains the information "AL,MOB", > however the callee contact is pstn in audiocodes, not the mobile number that > 201 talked. > > Is this a known issue? > I recall there is definitely some cdr code that looks at all the configured gateways and tries to resolve numbers. i'm not sure this helps you. have you searched jira for related issue?